Products and Services

Power station valve research and manufacturing

Hydraulic test plug valve

The valve in high temperature and high pressure conditions adopts the middle chamber pressure self-sealing structure, and the middle and low pressure adopt the middle chamber flange bolt sealing structure

Application
The plug valve of hydrostatic test is installed on the steam pipe of superheater outlet and reheater inlet and outlet of power plant boiler, and serves as the isolation device of static hydrostatic test. In the hydrostatic test, the inner parts such as plugging plate, O-type sealing ring and support plate are loaded to realize the sealing during the hydrostatic test. After the hydrostatic test is completed, remove the pressure test inner parts and load the diversion pipe parts into the pipe for use.
Characteristic
• The valve in high temperature and high pressure conditions adopts the middle chamber pressure self-sealing structure, and the middle and low pressure adopt the middle chamber flange bolt sealing structure;
• One side of the valve body processing plane sealing surface, the block plate is equipped with o-type sealing ring, hard seal and soft seal to achieve the joint action, pressure test seal reliable;
• When the pipeline is in normal operation, it is loaded into the diversion pipe to avoid eddy current generated by the medium in the valve and reduce flow resistance. The diversion pipe is designed with a pressure plate to press the diversion pipe to avoid vibration during operation;
• Two pressure test seal pretightening bolts are designed in the center and upper part of the block plate, and the upper pretightening bolts are rotated with a general wrench. The block plate can be pretightened by using a lever, without special tools and easy to operate;
• All inner parts are loaded from the top, easy to use and maintain; Hydraulic test inner parts can be disassembled and reused for many times, reducing cost and labor intensity.
Design Guides
Design and manufacture Pressure and temperature reference Inspection and test
NB/ T47044 NB/ T47044 NB/ T47044
ASME B16.34 ASME B16.34 ASME B16.34 MSS-SP-61

Product Range
Nominal pressure PN16~PN760(Class150—Class4500)
Nominal size DN10~DN1200(NPS 3/8~NPS 48)
Body matenal Forgings:20、A105、F22.CL3、F91、F92
Casting:WCB 、WC6、WC9、ZG20CrMoV
Test pressure(MPa) Strength test (Water pressure) 1.5×P(38℃ pressure rating)
Sealing test (Water pressure)) 1.5×Working Pressure
Applicable Temperature -29℃~650℃
Applicable medium Steam, water

Note:
1、The valve beyond the above specifications can be customized according to user requirements;
2、The applicable temperature range of each valve shall be subject to the actual pressure bearing material of the valve.